Cardiac Markers
CK-MB
The CK-MB (Creatine-Kinase MB) Test FIA is a quantitative test for fluorescence immunodetection of Creatine Kinase (CK-MB). This test is used to aid in the diagnosis of acute myocardial infarction. For IN VITRO diagnostic use only.
Results in up to 10 minutes
Sensitivity: 97.5%
Sample: Whole blood, serum, or plasma
Detection range: 0.2~75ng/ml
Specificity: 98.3%
Presentation: Kit with 10, 20, 25, or 30 tests
Anvisa Registration: 80638720152
Myoglobin
The Myoglobin Test FIA is a quantitative test for fluorescence immunodetection of Myoglobin (Myo). This test is used to aid in the diagnosis of acute myocardial infarction. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 98%
Sample: Whole blood, serum, or plasma
Detection range: 5~200ng/ml
Specificity: 98.4%
Presentation: Kit with 10, 20, 25, or 30 tests
Anvisa Registration: 80638720132
NT-proBNP
The NT-proBNP (N-terminal pro-brain natriuretic peptid) Test FIA is a quantitative test for fluorescence immunodetection of NT-proBNP. This test is used to aid in the diagnosis and/or monitoring of treatment for congestive heart failure (CHF). For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 97.9%
Sample: Whole blood, serum, or plasma
Detection range: 0.3~22ng/ml
Specificity: 98.3%
Presentation: Kit with 10, 20, 25, or 30 tests
Anvisa Registration: 80638720140
D-Dimer
The D-Dimer Test FIA is a quantitative test for fluorescence immunodetection of D-dimer. This test is used to aid in the diagnosis of disseminated intravascular coagulation (DIC), deep vein thrombosis (DVT), and pulmonary embolism. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 98.8%
Sample: Whole blood or plasma
Detection range: 0.1~10mg/l
Specificity: 100%
Presentation: Kit with 10, 20, 25, or 30 tests
Anvisa Registration: 80638720182
H-FABP
The H-FABP (Heart-type Fatty Acid Binding Protein) Test FIA is a quantitative test for fluorescence immunodetection of heart-type fatty acid binding proteins (FABP) in the heart. This test is used to aid in the diagnosis of acute myocardial infarction. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 97.9%
Sample: Whole blood or plasma
Detection range: 1~120ng/ml
Specificity: 98.4%
Presentation: Kit with 10 tests
Anvisa Registration: 80638720191
Troponin I
The Troponin I Test FIA is a quantitative test for fluorescence immunodetection of troponin I (cTnI). This test is used to aid in the diagnosis of acute myocardial infarction. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 98.1%
Sample: Whole blood, serum, or plasma
Detection range: 0.1~40ng/ml
Specificity: 96.7%
Presentation: Kit with 10 or 20 tests
Anvisa Registration: 80638720186