Hormone Panel
FSH
The FSH (Follicle-Stimulating Hormone) Test FIA is a quantitative test for fluorescence immunodetection of follicle-stimulating hormone (FSH). This test is used to aid in the diagnosis of menopause. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 97.8%
Sample: Whole blood, serum, or plasma
Detection range: 10~80mIU/ml
Specificity: 98.6%
Presentation: Kit with 10, 20, 25, or 30 tests
Anvisa Registration: 80638720138
LH
The LH (Luteinizing Hormone) Test FIA is a quantitative test for fluorescence immunodetection of luteinizing hormone (LH) in samples of whole blood, serum, or plasma. This test is used to aid in the diagnosis of menopause. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 97.8%
Sample: Whole blood, serum, or plasma
Detection range: 1.0~30mIU/ml
Specificity: 98.6%
Presentation: Kit with 10, 20, 25, or 30 tests
Anvisa Registration: 80638720139
T4
The T4 (Thyroxine) Test FIA is a quantitative test for fluorescence immunodetection of thyroxine hormone (T4). This test is used to aid in the evaluation of thyroid function. For IN VITRO diagnostic use only.
Results in 10 minutes
Sensitivity: 95.56%
Sample: Serum or plasma
Detection range: 12.87~300nmol/l
Specificity: 100%
Presentation: Kit with 10, 20, 25, or 30 tests
Anvisa Registration: 80638720144
Beta-HCG
The Beta-HCG (Human Chorionic Gonadotropin) Test FIA is a quantitative test for fluorescence immunodetection of human chorionic gonadotropin (hCG) in samples of serum or plasma. This test is used to aid in the diagnosis of pregnancy. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 98.2%
Sample: Whole blood, serum, or plasma
Detection range: 2~200,000mIU/ml
Specificity: 98.6%
Presentation: Kit with 10, 20, 25, or 30 tests
Anvisa Registration: 80638720141
TSH
The TSH (Thyroid-Stimulating Hormone) Test FIA is a quantitative test for fluorescence immunodetection of thyroid-stimulating hormone (TSH). This test is used to aid in the evaluation of thyroid function. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity: 95.7%
Sample: Serum or plasma
Detection range: 0.1~100μIU/ml
Specificity: 100%
Presentation: Kit with 10 tests
Anvisa Registration: 80638720193
T3
The T3 (Total Triiodothyronine) Test FIA is a quantitative test for fluorescence immunodetection of total triiodothyronine hormone (T3) in samples of serum or plasma. This test is used to aid in the evaluation of thyroid function. For IN VITRO diagnostic use only.
Results in up to 15 minutes
Sensitivity:
Below normal: 85.71%
Normal value: 96.15%
Above normal: 100%
Sample: Serum or plasma
Detection range: 0.46ng/ml (0.629.24nmol/l)
Specificity: 100%
Presentation: Kit with 10 and 20 tests
Anvisa Registration: 80638720187